Welcome to visit us!

[email protected]
Online service

Anytime 24/7

How to find us

Zhengzhou High-tech Zone, China

MENU
MENU
NEWS
  1. Home
  2. >
  3. Dryer Machine>
  4. flexible dryer vent hose length

flexible dryer vent hose length

Get shopping advice from experts friends and the community The dryer is a Whirlpool Model LER5620KQ1 The washer and dryer have to fit behind the door but the dryer sticks out too far by about an inch I was hoping to reduce the length of the vent hose because there is a lot of it back there and maybe the dryer would fit behind the door

Get a Quote Send Message

Hot Products

Please Leave A Message

More Details

DryerFlex Transition Duct
DryerFlex Transition Duct

For safety reasons and added peace of mind only UL2158A listed ducting like DryerFlex should be used to connect the dryers exhaust system nonlisted hose such as that commonly used to vent bathroom fans should never be used While building code and dryer manufacturers all require a UL 2158A listed transition duct there are differences

Learn More
Appliance411 FAQ How long can my dryer vent be
Appliance411 FAQ How long can my dryer vent be

Vent Types and Length Between 19801998 an average of 14500 fires per year are known to have been the result of dryers Those fires average 13 deaths 239 injuries and 531 million in property damage per year Im afraid the statistics arent getting much better and in

Learn More
Shorten your dryer hose to boost efficiency and save money
Shorten your dryer hose to boost efficiency and save money

Jan 27 2014 · Shorten your dryer hose to boost efficiency and save money By Drew Prindle GonzoTorpedo Posted on January 27 2014 218PM 12714 218PM If your dryer hose that big accordionlike metallic tube that connects it to the wall is longer than it should be it has to work harder and expend more energy to pump steam out of the machine

Learn More
Eliminate Fire Danger by Simple Dryer Vent Maintenance
Eliminate Fire Danger by Simple Dryer Vent Maintenance

However this standard is for flexible plastic and metal heating and cooling ductwork and vent fans such as those used in bathrooms These products are not approved for use as dryer vents Only flexible ductwork meeting UL 2158A can be used as dryer venting

Learn More
Aluminum Dryer Vent Hose
Aluminum Dryer Vent Hose

Dundas Jafine Dryer Vent Kit Elbow Periscope Tight Space Adjustable Length Aluminum 2244 In Sold by treehousedeals GE Universal SemiRigid Flexible Metal Dryer 8 Vent Hose Duct Crush Fire Resistant Sold by greatsavings4u2016 an eBay Marketplace seller 4065

Learn More
Dryer Vent Safety  InterNACHI
Dryer Vent Safety InterNACHI

The maximum developed length of a clothes dryer exhaust duct shall not exceed 35 feet from the dryer location to the wall or roof termination The maximum length of the duct shall be reduced 25 feet for each 45degree 08 rad bend and 5 feet for each 90degree 16 rad bend

Learn More
Dryer Vents  Accessories at
Dryer Vents Accessories at

Length Inches Compare IMPERIAL Outdoor Exhaust Dryer Vent Kit Item 433313 Model VTL0057 273 Write a review Find my store for pricing and availability 4in Dia Plastic R2 ExhaustIntake Dryer Vent Hood 4in Dia Plastic R2 Exhaust Dryer Vent Hood Builders Edge 6in Plastic Hood Dryer Vent Cap

Learn More
How to Get Dryer Vents Close to a Wall  Home Guides  SF
How to Get Dryer Vents Close to a Wall Home Guides SF

Dec 29 2018 · When installing a flexible hose measure the space between the dryer and the wall and cut the hose a few inches longer than you need The slight extra length of hose lets you to move the dryer out while you install the hose and the hose coils compress the hose evenly when you push the dryer close to the wall

Learn More
Whats the Maximum Length Allowed for a Dryer Vent
Whats the Maximum Length Allowed for a Dryer Vent

Oct 02 2012 · The International Residential Code IRC states that the maximum length for a dryer vent is 25 feet according to the National Association of Certified Home Inspectiors website However there are a lot of variables that can enter into the equation

Learn More
Do Dryer Vent Hoses Come in Different Sizes
Do Dryer Vent Hoses Come in Different Sizes

Dryer vent hoses vary in size but most used for residential dryers are between 4 and 5 inches in diameter Using a vent hose that is too small presents a fire risk while one that is too large can result in inefficient drying Keep Learning

Learn More
Snap to Vent Indoor Hookup Dryer Vent Kit at
Snap to Vent Indoor Hookup Dryer Vent Kit at

Universal dryer hookup for both electric and gas dryers also works with semi rigid or flexible dryer hose Product includes Snap to Vent straight one 90 elbow two snap connectors two seal rings and one 4 in diameter x 8 ft long hose optimal for connecting from dryer duct to wall vent duct

Learn More
Quietflex 4inch Flexible Dryer Vent Duct 25 Foot Section
Quietflex 4inch Flexible Dryer Vent Duct 25 Foot Section

CE Compass Aluminum Ducting Dryer Vent Hose 4 Inch 8FT Flexible NonInsulated Air Hose HVAC Ventilation Cooling Intake Exhaust Pipe 0 Sold by CE COMPASS INC

Learn More
Is there a minimum length that the vent hose has to be
Is there a minimum length that the vent hose has to be

The dryer is about 28 inches deep and that would only leave a space of 2 12 inches for the 4 inch diameter vent hose You may not be able to get the dryer to fit behind the door due to the limited depth of the location You do not want to shut the door when using the dryer unless the door is vented

Learn More
Dryer Vent Safety  Installation Guide Clothes dryer vent
Dryer Vent Safety Installation Guide Clothes dryer vent

An exception to this length reduction for dryer vent elbows may be permitted for largeradius bend dryer vent products such as DryerEll Thats because a normal 4inch 90degree metal dryer vent elbow bends 90 degrees in a 4inch radius while the DryerEll product makes its bend over a

Learn More
Installing SemiRigid Dryer Hose to   Pretty Handy Girl
Installing SemiRigid Dryer Hose to Pretty Handy Girl

Detach the dryer duct hose from the wall inside your home first Use the screwdriver to loosen the hose clamp Or if you have the tension style clamp pinch the clamp wings together to release the hose Head back outside Unscrew the mounting screws from around the dryer vent and lift the dryer vent off

Learn More
Dryer Transition Ducts Is Foil Better Than SemiRigid
Dryer Transition Ducts Is Foil Better Than SemiRigid

Apr 13 2010 · All the products marketed for dryers cater to the ideal scenario where your dryer is 8′ or less from the terminus although it IS possible to purchase 25′ length of Deflecto transition flex I’ve replaced a some ducts with rigid galvanized foil taped joints and insulated them with Reflectix

Learn More
What’s Wrong With Plastic Dryer Vents  House Detective
What’s Wrong With Plastic Dryer Vents House Detective

Sep 02 2013 · The fittings should be secured with tape rather than screws because screws on the inside of a dryer duct can collect lint The maximum permissible length of the duct is 14 feet with a maximum of two 90degree turns For each additional turn two feet should be subtracted from the overall length

Learn More
Clothes Dryer Vents The Proper and the Improper
Clothes Dryer Vents The Proper and the Improper

Most standards call for clothes dryer vents to be no more than 25 feet in length have few bends and no kinks Gas dryers though are often permitted to have ducts no longer than 35 feet in length The more bends in the line that exist the shorter the overall length should be

Learn More
Dryer  Installation Information for Exhaust Ducting
Dryer Installation Information for Exhaust Ducting

A ULlisted semirigid dryer duct can be used if the vent length is 8 feet or less We have a semirigid flexible transition dryer duct part PM08X10085 ULlisted foil dryer ducts are only allowed under very strict criteria For example foil dryer ducts can only be used in

Learn More
Flexible Venting  Ductwork  FW Webb Online Ordering
Flexible Venting Ductwork FW Webb Online Ordering

Flexible Venting Ductwork Lambro 344 Dryer Vent with Tailpiece and Sleeve 4 Aluminum Dryer Vent Hose Receptacle 397 ea Qty Add to Cart Guests In Stock Ships in 1 Business Day Lambro 316W Vent Kit 316W Flexible Semi Rigid 4 Inch x 8 Feet for Dryer

Learn More
The Allowable Length of a Dryer Vent  eHow
The Allowable Length of a Dryer Vent eHow

When using a straight piece of flexible metal vent hose the maximum length allowed for safe ventilation is approximately 30 feet according to the Appliance Aid website While the lint should escape and prevent overheating at this length it is preferable to go with a shorter length if the arrangement of your appliances will allow for it

Learn More
Dryer Vent Hose Length Considerations
Dryer Vent Hose Length Considerations

Dryer Vent Hose Length Considerations They state that a straight duct be no longer than 25 feet In addition if there is a 45 degree bend then deduct 25 feet from the recommended length and if there is a 90 degree bend deduct 5 feet So if you have a space that will need two 90 degree bends then you should have no more than 15’ of dryer duct Comments

Learn More
10 Best Dryer Vent Hose for Tight Space  Smart Home Pick
10 Best Dryer Vent Hose for Tight Space Smart Home Pick

Jul 28 2018 · MagVent MV90 Magnetic Dryer Vent 89 inches length by 54 inches diameter Aluminum Not very flexible Dryer Vent Tite Fit 90 Degree 18 to 30 6 inches length 2 inches diameter Aluminum Rigid iPower 6 Inch 8 Feet NonInsulated Flex Air 6 inches length 8 feet diameter Aluminum Yes Whirlpool 8171587RP Dryer Vent Periscope

Learn More
Best Dryer Vent Hose 2019
Best Dryer Vent Hose 2019

May 10 2018 · iPower 4 Inch 8 Feet NonInsulated Flex Air Aluminum Ducting Dryer Vent Hose It’s a good price and good value for what you get but it isn’t designed to be incredibly long lasting or offer a lot of quality features that make it a good investment This

Learn More
BrightNest  Shorten Your Dryer Vent Hose
BrightNest Shorten Your Dryer Vent Hose

Inspect your dryer duct and vent hose Take a quick look for kinks holes or other damage if you find any it may be worth replacing your hose entirely Then carefully detach the vent hose Optional This is a great time to clean your vent and duct by vacuuming the back of the dryer the dryer

Learn More
Flexible Clothes Dryer Duct  20 Foot by 4
Flexible Clothes Dryer Duct 20 Foot by 4

Duct Hose 4 inch by 12 feet Abuff Flexible 4Layers Aluminum Dryer Vent Tube Transition Duct with 2 Screw Clamps Great as HVAC Duct Clothes Dryer Duct Air Duct

Learn More
4 Ways to Install a Dryer Vent Hose  wikiHow
4 Ways to Install a Dryer Vent Hose wikiHow

Mar 29 2019 · Hold the vent hose down with pipe straps When the dryer vent hose is fully attached make sure all the seams are covered with foil tape Then press the dryer vent to the wall and hold it down using pipe straps and simple screws For safety use

Learn More
length of a dryer vent  This Old House
length of a dryer vent This Old House

Re length of a dryer vent Good to hear you are using the rigid ducting Every 90 degree elbow adds restriction approx 45 feet of equivalent length to the duct So in theory that would add approx 1620 feet of ducting to the 10 feet you have to go equaling around 2630 of equivalent distance which is around the maximum from a dryer

Learn More
GE Flexible Metal Dryer DuctPM08X10085DS  The Home
GE Flexible Metal Dryer DuctPM08X10085DS The Home

Internet 205472610 The flexible metal dryer transition duct is designed for both top load and front load dryers Semirigid flexible metal design allows for 90degree turns Crush resistant to

Learn More

The Latest News